1.SC Codes
563
Solution
1. Turn the power OFF and ON.
2. Check the connector.
Check the connection between the punch entrance roller lift motor/punch entrance roller lift HP
sensor and main board. (Check all the connectors are completely connected.)
3. Check the harness.
Check the harness between the punch entrance roller lift motor/punch entrance roller lift HP sensor
and main board.
If the harness is damaged or exposed, replace it. Turn the power OFF/ON, and then check if the
SC recurs.
4. Replace the components.
ï‚· If the punch entrance roller lift motor does not operate, replace the motor.
ï‚· If the punch entrance roller lift HP sensor does not react, replace the sensor.
ï‚· If the main board on the ring binder is defective, replace the board.
SC756-30
Error Name
Ring Binder: Paddle Roller HP Error
Pattern
B
Error Condition
ï‚· The paddle roller moved from home position, but home position is detected even after a specified
time had passed. (The first time is reported as a jam. An SC is issued the second time this occurs.)
ï‚· The paddle roller has moved to the home position, but home position is not be detected within a
specified time. (The first time is reported as a jam. An SC is issued the second time this occurs.)
* The first time: Pre-punch jogger jam (J343)
Major Cause
ï‚· Power of downstream unit not turned on
ï‚· Motor defective (Paddle roller lift motor)
ï‚· Connector disconnected
ï‚· Overload
ï‚· Home position sensor defective (Paddle roller HP sensor)
Solution
1. Turn the power OFF and ON.
2. Check the connector.