1.SC Codes
509
Major Cause
ï‚· Glue vat roller motor defective
ï‚· Glue vat roller rotation sensor connector defective
ï‚· Connector loose, damaged, or defective
ï‚· Slave control board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the vat roller motor.
ï‚· Replace the vat roller rotation sensor.
ï‚· Replace the slave control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC754-12
Error Name
Perfect Binder: Glue Roller HP Sensor Late Error
Pattern
B
Error Condition
During glue supply, the glue roller HP sensor did not go ON, even though the glue roller motor was
operating for 1000 ms.
Major Cause
ï‚· Glue pellets jammed
ï‚· Glue supply motor defective
ï‚· Glue roller HP sensor defective
ï‚· Connector loose, damaged, or defective
ï‚· Slave control board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the glue supply motor.
ï‚· Replace the glue roller HP sensor.
ï‚· Replace the slave control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.