1.SC Codes
354
SC750-79
Error Name
Perfect Binder: Low Temperature Detection Error
Pattern
D
Error Condition
After adjustment of the glue temperature, the glue temperature thermistor detected a temperature lower
than 135 degrees for more than 10 sec.
Major Cause
ï‚· Glue temperature thermistor defective
ï‚· Glue heater defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the gluing unit.
ï‚· Replace the slave board.
SC750-80
Error Name
Perfect Binder: High Temperature Error
Pattern
D
Error Condition
Thermistor detected abnormal high temperature.
Major Cause
ï‚· Glue abnormal temperature thermistor defective
ï‚· Glue heater defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the gluing unit.
ï‚· Replace the slave board.