1.SC Codes
507
SC753-89
Error Name
Perfect Binder: Signature thickness sensor maximum value error
Pattern
B
Error Condition
When the result of the signature thickness detection (A/D value) was adjusted, the maximum value
(25mm) was smaller than the A/D value.
Major Cause
ï‚· Signature thickness sensor defective
ï‚· Connector loose, broken, defective
ï‚· Slave control board defective
ï‚· Master control board defective
ï‚· EEPROM on the master board defective
Solution
ï‚· Reconnect the connector.
ï‚· Specify the signature thickness again.
ï‚· Replace the signature thickness sensor.
ï‚· Replace the EEPROM on the master board.
ï‚· Replace the slave control board.
ï‚· Replace the master control board.
ï‚· Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power off/on.