1.SC Codes
322
was closed. (Relay circuit failed to go ON.)
Major Cause
ï‚· Front door L/R SW is defective.
ï‚· Master control board is defective.
Solution
ï‚· Reconnect the connector.
ï‚· Replace the front door L/R SW.
ï‚· Replace the master control board.
ï‚· Replace the sensor harness.
SC750-21
Error Name
Perfect Binder: 24V Check Signal Error 2
Pattern
D
Error Condition
Front door L/RWS and top cover sensor are closed, but the top cover switch is open, or the 24V2
monitoring signal of the master control board was OFF for more than 5 sec, (Top cover sensor or top
cover switch is defective.)
Major Cause
ï‚· Front door L/RSW defective
ï‚· Top cover switch defective
ï‚· Top cover sensor defective
ï‚· Master board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the front door L/RSW.
ï‚· Replace the top cover switch
ï‚· Replace the top cover sensor.
ï‚· Replace the master control board.
ï‚· Replace the sensor harness.