1.SC Codes
480
Major Cause
ï‚· Glue level thermistor defective
ï‚· Glue heater defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the gluing unit.
ï‚· Replace the slave board.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC753-46
Error Name
Perfect Binder: Glue level thermistor error 2
Pattern
B
Error Condition
After glue warm-up completed, the glue level thermistor detected a temperature less than 100 degrees
for more than 10 sec.
Major Cause
ï‚· Glue level thermistor defective
ï‚· Glue heater defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the gluing unit.
ï‚· Replace the slave board.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC753-47
Error Name
Perfect Binder: Thermistor disconnect error
Pattern
B