1.SC Codes
171
Error Condition
The frequency of the commercial power supply is detected to be 66 Hz or more.
Major Cause
There is unstable noise in the frequency of the commercial power supply.
Solution
Nothing can be done.
SC559-00
Error Name
Fusing Jam: 3 Counts
Pattern
A
Error Condition
Fusing jam (fusing exit sensor late jam): JAM034 is detected three times consecutively.
Each occurrence of a fusing jam is counted and SC559-00 is issued when the count reaches 3.
The fusing jam counter is not reset even if the machine is turned OFF and ON.
Major Cause
ï‚· There are foreign objects in the transport path, or the transport path is dirty
(Such as remaining paper at fusing unit, paper wrapped around fusing belt, fusing belt dirty,
separation plate dirty, foreign object on the guide plate or guide plate dirty.)
ï‚· Fusing Unit Exit Sensor (SEN63) is defective.
Solution
1. Check the transport path (paper wrapped around fusing belt, fusing belt dirty, separation plate dirty,
foreign object on the guide plate or guide plate dirty). Clean the path.
2. Replace the fusing unit exit sensor (SEN63).
SC560-00
Error Name
Fusing Temperature Sensor (Heating Roller End) Defective (Sensor 10)
Pattern
A