1.SC Codes
252
Replace the board. (Board replacement is required for this error.)
SC721-06
Error Name
NVRAM Access Error (Finisher SR5090/Booklet Finisher SR5100)
Pattern
B
Error Condition
An error occurred during access to the NV memory of the Finisher SR5090/Booklet Finisher SR5100.
Major Cause
ï‚· Power of downstream unit is off.
ï‚· NV memory not installed properly, or is defective.
Component: NV memory, Controller Board
Solution
1. NV memory not installed properly, or defective.
Turn the main power to OFF, check that the NV memory is connected to the IC socket correctly by
inserting and removing the memory.
2. Replace the controller board.
SC721-10, 11, 13, 15, 17
Error Name
ï‚· 721-10: Entrance Transport Motor Error (Finisher SR5090/Booklet Finisher SR5100)
ï‚· 721-11: Horizontal Transport Motor Error (Finisher SR5090/Booklet Finisher SR5100)
ï‚· 721-13: Transport Motor Error (Finisher SR5090/Booklet Finisher SR5100)
ï‚· 721-15: Pre-stack Transport Motor Error (Finisher SR5090/Booklet Finisher SR5100)
ï‚· 721-17: Exit Motor Error (Finisher SR5090/Booklet Finisher SR5100)
Pattern
ï‚· 721-10: D
ï‚· 721-11: D
ï‚· 721-13: B
ï‚· 721-15: D
ï‚· 721-17: B
Error Condition
DC motor control error is detected. (The first four times are reported as jams. An SC is issued when it is