1.SC Codes
592
necessary.
1. Reconnect the connector.
2. Replace the vertical transport motor cooling fan on LCT2.
3. Replace the harness.
4. Replace the PCB.
SC781-09
Error Name
LCT2: Transport Motor Cooling Fan Error (Vacuum Feed LCIT)
Pattern
B
Error Condition
Cooling fan alarm “H (error)” is detected while the transport motor cooling fan on LCT2 is ON.
Major Cause
Power of downstream unit is not turned on.
Transport motor cooling fan on LCT2 defective / connector disconnected
Harness damaged
PCB defective
Solution
In addition to checking for sensor/actuator defect by eye, also execute Input/Output Check as
necessary.
1. Reconnect the connector.
2. Replace the transport motor cooling fan on LCT2.
3. Replace the harness.
4. Replace the PCB.
SC781-51
Error Name
LCT2: Unit Configuration Error (Bridge Unit Connection Error)
Pattern
D
Error Condition
The bridge unit is connected to LCT2, but there is no LCT3.