1.SC Codes
432
Error Condition
When signature was passed from main grip to signature exit roller, signature exit sensor did not go ON
after MG lift motor moved to signature turnover position.
Major Cause
ï‚· MG lift motor defective
ï‚· Signature exit sensor defective
ï‚· Signature out of position, or snagged on main grip
Solution
ï‚· Reconnect the connector.
ï‚· Replace the MG lift motor.
ï‚· Replace the signature exit sensor.
ï‚· Replace the slave control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.
ï‚· Clear the signature jam.
SC752-49
Error Name
Perfect Binder: Main Grip HP Sensor (L) Late Error
Pattern
D
Error Condition
During main grip lift, the MG HP sensor (L) did not go ON, even though the main grip lift motor had
operated for 6185 ms.
Major Cause
ï‚· MG lift motor defective
ï‚· MG HP sensor (L) defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the MG lift motor.
ï‚· Replace the MG HP sensor (L).
ï‚· Replace the slave control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.