1.SC Codes
320
Error Condition
When data was written to the EEPROM, the EEPROM signaled that it was busy for longer than 25 ms
and did not recover.
Major Cause
ï‚· EEPROM defective
ï‚· EEPROM not installed
Solution
ï‚· Install the master control board EEPROM.
ï‚· Replace the master control board EEPROM.
ï‚· Replace the master control board.
SC750-17
Error Name
Perfect Binder: Master-to-Inserter Initial Communication Error
Pattern
D
Error Condition
Inserter connection was detected, but initial communication was not completed within 5 sec after the
ConfigSet (parallel signal) went ON.
Major Cause
ï‚· Inserter board defective
ï‚· Connector loose, damaged, or defective.
Solution
ï‚· Reconnect the connector.
ï‚· Replace the master control board.
ï‚· Replace the inserter board.
ï‚· Replace the harness.
SC750-18
Error Name
Perfect Binder: Master-to-Inserter Board Communication Error
Pattern
D