1.SC Codes
353
Pattern
D
Error Condition
A temperature of less than 5 degrees was detected for 1 sec. or more than 10 sec. (after power ON.)
If the thermistor detects less than 100 degrees after measuring temperature at start up, temperature is
checked again after 50 sec.
Major Cause
ï‚· Glue temperature thermistor defective
ï‚· Glue heater defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the gluing unit.
ï‚· Replace the slave board.
SC750-78
Error Name
Perfect Binder: Glue Heater Startup Error 1
Pattern
D
Error Condition
Glue temperature thermistor does not detect a temperature of 140 degrees within 200 sec. after it
detected a temperature of over 50 degrees.
Major Cause
ï‚· Glue temperature thermistor defective
ï‚· Glue heater defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the gluing unit.
ï‚· Replace the slave board.