1.SC Codes
595
Solution
Configurate the units as follows:
Main machine + LCT 1 + bridge unit 1 + RPIP interface box
SC790-10
Error Name
EEPROM Download Error
Pattern
D
Error Condition
CRC error occurred 4 times when data is downloaded from EEPROM.
Major Cause
ï‚· Power of downstream unit is not turned on.
ï‚· Last parameter writing failed.
ï‚· Board on the RPIP Interface Box defective
Solution
1. Turn the power OFF and then ON.
2. If the problem is not solved in Step 1, repeat parameter writing.
3. If the problem is not solved in Step 2, replace the board on the RPIP interface box.