1.SC Codes
208
SC700-07
Error Name
Scan Motor Error (1-Pass ADF)
Pattern
D
Error Condition
An error signal is detected while the ADF scan motor [M6] is driven.
Major Cause
ï‚· ADF scan motor [M6] is defective.
ï‚· Connector is disconnected.
ï‚· Harness is damaged.
ï‚· Motor is overloaded.
Solution
1. Connectors not connected properly
Check that all the connectors on the board and of the motor are properly connected. (connectors
not disconnected or half-inserted)
Reconnect the connectors.
2. Harness damaged
Check if the harness between the board and the motor is damaged or exposed.
Replace the harness if it is not in good condition.
3. Motor defective
Check that the motor can be rotated as a single component, and its drive is transmitted to other
components. Also check if the motor is overloaded.
If the motor is defective, replace it.
4. Board defective
Check if there are any traces of short circuit on the board. If so, replace the ADF control board.