1.SC Codes
153
ï‚· 515-12: Tray 1 Vertical Transport Exit Contact Motor Error
ï‚· 515-13: Vertical Transport Entrance Contact Motor Error
ï‚· 515-14: Tray 2 Vertical Transport Exit Contact Motor Error
Pattern
B
Error Condition
The status of the contact sensor does not change when the contact motor is running.
Major Cause
ï‚· Power of the downstream unit is not turned on
ï‚· Corresponding motors are defective or not connected properly.
ï‚· Contact sensor is defective or not connected properly.
ï‚· Harnesses are damaged.
ï‚· PCB is defective.
Corresponding Motors:
ï‚· 515-05: Vacuum Feed LCIT 1 Contact Motor
ï‚· 515-06: Vacuum Feed LCIT 2 Contact Motor
ï‚· 515-07: Tray 1 Vertical Transport Contact Motor
ï‚· 515-08: Tray 1 Vertical Transport Exit Contact Motor
ï‚· 515-09: Vertical Transport Entrance Contact Motor
ï‚· 515-10: Tray 2 Vertical Transport Exit Contact Motor
ï‚· 515-11: Tray 1 Vertical Transport Contact Motor
ï‚· 515-12: Tray 1 Vertical Transport Exit Contact Motor
ï‚· 515-13: Vertical Transport Entrance Contact Motor
ï‚· 515-14: Tray 2 Vertical Transport Exit Contact Motor
Solution
In addition to checking for sensor/actuator defect by eye, also execute Input/Output Check as
necessary.
1. Check the connector of the harness of the contact sensor.
Reconnect the connector. Turn the main power OFF and then ON.
2. Check the connector of the harness of the contact motor.
Reconnect the connector. Turn the main power OFF and then ON.
3. Check the contact sensor.
If it is defective, replace it. Turn the main power OFF and then ON.
4. Check the harnesses.
If the harnesses are defective, replace the harnesses. Turn the main power OFF and then ON.
5. Check the contact motor.