Remote control commands
R&S
®
RTP
2192User Manual 1337.9952.02 ─ 12
Suffix:
<m>
.
1..4
Parameters:
<Condition> LTHan | GTHan
*RST: GTHan
Usage: Asynchronous command
EYE<m>:QUALify:SIGNal:LSELect <LevelSelection>
Selects the threshold. You can use the lower, middle, or upper reference level. These
levels are the reference levels that are defined for measurements.
Suffix:
<m>
.
1..4
Parameters:
<LevelSelection> UPPer | MIDDle | LOWer
*RST: MIDDle
Example: The slices of the channel 1 signal only contribute to the eye gen-
eration if the voltage level of the signal on channel 2 is higher
than the upper reference level.
EYE:SOURce C1W1
EYE:QUALify:SIGNal:SOURce C2W1
EYE:QUALify:SIGNal:CONDition GTHan
EYE:QUALify:SIGNal:LSELect UPPer
EYE:QUALify:SIGNal ON
Usage: Asynchronous command
Filter
EYE<m>:FILTer:STATe................................................................................................. 2192
EYE<m>:FILTer:BPATtern:MODE.................................................................................. 2193
EYE<m>:FILTer:BPATtern:PREFix<1..8>........................................................................2193
EYE<m>:FILTer:BPATtern:CENTer.................................................................................2193
EYE<m>:FILTer:BPATtern:SUFFix<1..5>........................................................................ 2193
EYE<m>:FILTer:BPATtern:SLEFt................................................................................... 2193
EYE<m>:FILTer:BPATtern:SRIGht................................................................................. 2194
EYE<m>:FILTer:BPATtern:RESet...................................................................................2194
EYE<m>:FILTer:DDR:FTYPe.........................................................................................2194
EYE<m>:FILTer:DDR:LENerror..................................................................................... 2194
EYE<m>:FILTer:STATe <State>
Applies the filter settings to the data signal.