Protocol analysis
R&S
®
RTP
766User Manual 1337.9952.02 ─ 12
Remote command:
TRIGger<m>:CMSB:PATTern on page 1948
TRIGger<m>:CMSB:ICONdition on page 1948
TRIGger<m>:CMSB:IMIN on page 1948
TRIGger<m>:CMSB:IMAX on page 1949
BUS<m>:CMSB:GAPTime:VALue on page 1941
TRIGger<m>:CMSB:NRZ:WRDLength on page 1949
Advanced
Trigger on various frame types, fields in the frames, and data patterns.
Which settings are available, depends on what you have defined in the "Format" tab.
You can further refine the trigger criteria, selecting which frames you want to select for
the triggering and what conditions their field values must fulfill.
Error types: Item name, Enable ← Advanced
The table lists the error types you can trigger on. Select the required errors in the
"Enable" column. Available are "CRC" error and "Parity" error.
Remote command:
TRIGger<m>:CMSB:ADVanced:ERENable on page 1951
TRIGger<m>:CMSB:ADVanced:ERRor<n>:ENABle on page 1951
Frame type ← Advanced
Selects the frame type for the custom bus trigger analysis.
Custom: Manchester / NRZ (option R&S
RTP-K50)M