Protocol analysis
R&S
®
RTP
816User Manual 1337.9952.02 ─ 12
"Unexpected
PID error"
Triggers on any illegal PID. This is a PID that is not allowed in USB
low speed and USB full speed protocols, especially PID's announcing
packets such as SPLIT, DATA2, MDATA, or other noncompliant pack-
ets.
"SE1 error"
Triggers on the illegal bus state Single Ended 1 (SE1 = both lines
high).
"Glitch error"
Triggers on an error in the bit period (see USB standard for the defini-
tion of glitch).
Remote command:
TRIGger<m>:USB:ERRC on page 2012
PID error
Defines, whether a packet ID error check is executed or not.
Remote command:
TRIGger<m>:USB:WPID on page 2018
End Point
Defines, whether an endpoint check that meets specific conditions is executed or not.
"Condition"
Defining a specific endpoint or an endpoint range requires to set the
operator to one of the following: equal, not equal, less than, less than
or equal, greater than, greater than or equal, in range, out of range.
"Min"
Specifies an endpoint, or sets the start value of an endpoint range.
"Max"
Sets the end value of an endpoint range if "Condition"
(TRIGger<m>:USB:ECONdition) is set to INRange or OORange.
Remote command:
TRIGger<m>:USB:WEND on page 2017
TRIGger<m>:USB:ECONdition on page 2011
TRIGger<m>:USB:EMIN on page 2011
TRIGger<m>:USB:EMAX on page 2011
Address
Defines, whether an address check that meets specific conditions is executed or not.
"Condition"
Defining a specific address or an address range requires to set the
operator to one of the following: equal, not equal, less than, less than
or equal, greater than, greater than or equal, in range, out of range.
"Min"
Specifies an address, or sets the start value of an address range.
"Max"
Sets the end value of an address range if "Condition" (TRIGger<m>:
USB:ACONdition) is set to INRange or OORange.
Remote command:
TRIGger<m>:USB:WADD on page 2017
TRIGger<m>:USB:ACONdition on page 2009
TRIGger<m>:USB:AMAX on page 2010
TRIGger<m>:USB:AMIN on page 2009
USB (option R&S
RTP-K60)