Remote Control Commands
R&S
®
SMBV100B
721User Manual 1178.4460.02 ─ 03
Parameters:
<Angle> float
Range:  0  to  180
Increment:  0.01
*RST:  0
Default unit: Deg
Example: 
BB:DM:FORM AQPS
BB:DM:AQPS:ANGL 45
Manual operation:  See "Angle Alpha" on page 123
[:SOURce<hw>]:BB:DM:ASK:DEPTh <Depth>
Sets the ASK modulation depth for modulation type ASK.
Parameters:
<Depth> float
Range:  0  to  100
Increment:  0.1
*RST:  100
Default unit: PCT
Example: 
BB:DM:FORM ASK
BB:DM:ASK:DEPT 50 PCT
Manual operation:  See "ASK Depth" on page 123
[:SOURce<hw>]:BB:DM:FSK:DEViation <Deviation>
Sets the frequency deviation when FSK modulation is selected.
Parameters:
<Deviation> float
The value range depends on the symbol rate.
Range:  1  to  40E6
Increment:  0.5
*RST:  135416.5
Example: 
SOURce:BB:DM:FORMat FSK4
 SOURce:BB:DM:FSK:DEViation 1MHZ
Manual operation:  See "FSK Deviation" on page 123
[:SOURce<hw>]:BB:DM:FSK:VARiable:SYMBol<ch0>:DEViation <Deviation>
Sets the deviation of the selected symbol for variable FSK modulation mode.
SOURce Subsystem