Remote Control Commands
R&S
®
SMBV100B
722User Manual 1178.4460.02 ─ 03
Parameters:
<Deviation> float
The value range depends on the selected symbol rate (see data
sheet).
Range: -40E6 to 40E6
Increment: 0.5
Default unit: Hz
Example:
SOURce:BB:DM:FORMat FSKVar
SOURce:BB:DM:FSK:VARiable:TYPE FSK4
SOURce:BB:DM:FSK:VARiable:SYMBol0:DEViation 135000
Manual operation: See "Deviation xxxx" on page 124
[:SOURce<hw>]:BB:DM:FSK:VARiable:TYPE <Type>
The command selects the modulation type for Variable FSK.
Parameters:
<Type> FSK4 | FSK8 | FSK16
*RST: FSK4
Example: See [:SOURce<hw>]:BB:DM:FSK:VARiable:
SYMBol<ch0>:DEViation on page 721
Manual operation: See "FSK Type" on page 123
[:SOURce<hw>]:BB:DM:APSK16:GAMMa <Gamma>
Sets the gamma function γ for the 16APSK modulation.
Parameters:
<Gamma> G2D3 | G3D4 | G4D5 | G5D6 | G8D9 | G9D10
GxDy: G = Gamma function, xy = code rate
*RST: G2D3
Example:
SOURce1:BB:DM:FORMat APSK16
SOURce1:BB:DM:APSK16:GAMMa G9D10
Manual operation: See "Gamma/Gamma 1" on page 124
[:SOURce<hw>]:BB:DM:APSK32:GAMMa <Gamma>
Sets the gamma function γ for the 32APSK modulation.
Parameters:
<Gamma> G3D4 | G4D5 | G5D6 | G8D9 | G9D10
GxDy: G = Gamma function, xy = code rate
*RST: G3D4
SOURce Subsystem

Table of Contents