Remote Control Commands
R&S
®
SMBV100B
781User Manual 1178.4460.02 ─ 03
SOURce:BB:MCCW:EDIT:CARRier:STARt 40
SOURce:BB:MCCW:EDIT:CARRier:STOP 80
SOURce:BB:MCCW:EDIT:CARRier:STATe OFF
SOURce:BB:MCCW:EDIT:CARRier:EXECute
// Configure the carrier table for the single sideband signal:
// Set the carriers no. 40 to 80 to "OFF"
SOURce:BB:MCCW:STATe ON
// Enable signal generation
OUTPut ON
// Enable signal output
Generating a composed multi-carrier signal
This example generates a multi-carrier signal as shown in Figure 12-2.
Figure 12-2: Composed multi-carrier signal
// ******************************************************************
// Reset the instrument first
// ******************************************************************
*RST; *CLS
// ******************************************************************
// Configuring the multi-carrier signal
// ******************************************************************
SOURce:BB:MCCW:CARRier:COUNt 100
SOURce:BB:MCCW:CARRier:SPACing 500000
// Setup 100 carriers with a spacing of 500kHz
SOURce:BB:MCCW:CLOCk?
// Return value 128000000
SOURce Subsystem