EasyManua.ls Logo

Rohde & Schwarz SMBV100B - Page 867

Rohde & Schwarz SMBV100B
1030 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
SMBV100B
865User Manual 1178.4460.02 ─ 03
Example: Using pulse generator as source for pulse modulation
// select pulse generator as source for pulse modulation
// enable pulse modulation
SOURce1:PULM:SOURce INT
SOURce1:PULM:STATe 1
// pulse generator and signal output are also activated
SOURce1:PGENerator:STATe?
// 1
SOURce1:PGENerator:OUTPut:STATe?
// 1
PGENerator:OUTPut:POLarity NORMal
// to disable pulse generator
SOURce1:PGENerator:STATe 0
// activate the pulse modulation of the RF carrier
SOURce1:PULM:STATe 1
[:SOURce<hw>]:PGENerator:OUTPut:POLarity................................................................ 865
[:SOURce<hw>]:PGENerator:OUTPut[:STATe]..................................................................865
[:SOURce<hw>]:PGENerator:STATe................................................................................ 866
[:SOURce<hw>]:PGENerator:OUTPut:POLarity <Polarity>
Sets the polarity of the pulse output signal.
Parameters:
<Polarity> NORMal | INVerted
NORMal
Outputs the pulse signal during the pulse width, that means dur-
ing the high state.
INVerted
Inverts the pulse output signal polarity. The pulse output signal is
suppressed during the pulse width, but provided during the low
state.
*RST: NORMal
Example: See Example "Using pulse generator as source for pulse modu-
lation" on page 865.
Manual operation: See "Pulse Output Polarity" on page 362
[:SOURce<hw>]:PGENerator:OUTPut[:STATe] <State>
Activates the output of the pulse modulation signal.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Using pulse generator as source for pulse modu-
lation" on page 865.
SOURce Subsystem

Table of Contents

Related product manuals