Remote Control Commands
R&S
®
SMBV100B
908User Manual 1178.4460.02 ─ 03
Return values: 
<IdList> string
Comma-separated string of the parameter identifiers (<Id>)
Example:  See :SYSTem:SPECification? on page 906.
Usage:  Query only
:SYSTem:SPECification:PARameter? <Id>[, <Parameter>]
Retrieves data sheet information for a specific parameter.
Setting parameters: 
<Id> string
Identifies the name of the entry in the data sheet.
Query the data sheet parameters with the command :SYSTem:
SPECification:IDENtification:CATalog?.
<Parameter> float
An additional value the result (ValList) depends on.
Return values: 
<ValList> float
Comma-separated list with the specified and, if available, the
typical value of the parameter, as specified in the data sheet.
Example:  Note: The following values are merely an example. Your instru-
ment may not support the same parameters.
SYST:SPEC:PAR? "ID_RF_FREQ_SETTING_TIME_MS",0.1
SYST:SPEC:PAR? "ID_RF_LEVEL_MAX_GENERAL_DBM",
0.1
Usage:  Query only
:SYSTem:SPECification:VERSion:CATalog?
Queries all data sheet versions stored in the instrument.
Return values: 
<VersCatalog> string
Example:  See :SYSTem:SPECification? on page 906.
Usage:  Query only
:SYSTem:SPECification:VERSion:FACTory?
Queries the data sheet version of the factory setting.
Return values: 
<Version> string
Example:  See :SYSTem:SPECification? on page 906.