1. FUNCTIONS AND CONFIGURATION
1 - 8
Note 1.
0.3 A is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of
I/O points.
2.
When closely mounting the drivers, operate them at the ambient temperature of 0 ˚C to 45 ˚C or at 75% or smaller effective
load ratio.
3.
Test pulse is a signal which instantaneously turns off a signal to the driver at a constant period for external circuit to self-
diagnose.
4.
Except for the terminal block.
5.
This value is applicable when a 3-phase power supply is used.
7.
When using 1-phase 200 V AC to 240 V AC power supply, operate the driver at 75% or smaller effective load ratio.
9.
Follow the restrictions in section 2.6 when using this product at altitude exceeding 1000 m and up to 2000 m above sea level.
10.
The safety level depends on the setting value of [Pr. PF18 STO diagnosis error detection time] and whether STO input
diagnosis by TOFB output is performed or not. For details, refer to the Function column of [Pr. PF18] in section 5.2.6.