EasyManua.ls Logo

SMC Networks LECSN-T Series - 19.7.3.3 Assembly Objects

SMC Networks LECSN-T Series
1046 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19 - 123
19EtherNet/IP COMMUNICATION
19.7.3.3 Assembly Objects
(1) Assembly Object (Class ID: 04h)
Ins ID
Attr ID
Access
Name
Data Type
0
1
Get
Revision
UINT
2
Get
Max Instance
3
3
Set
Data
4
Get
Size
UINT
4
3
Set
Data
4
Get
Size
UINT
5
3
Set
Data
4
Get
Size
UINT
6
3
Set
Data
4
Get
Size
UINT
7
3
Set
Data
4
Get
Size
UINT
100 to
106
3
Set
Data
BYTE array
4
Get
Size
UINT
150 to
156
3
Set
Data
BYTE array
4
Get
Size
UINT
Ins ID
Attr ID
Default
Range
Units
EEP-ROM
Parameter
0
1
0002h
0002h to 0002h
Impossible
2
0000h to 009Ch
3
3
No data
4
0
0000h to 0000h
4
3
No data
4
0
0000h to 0000h
5
3
4
0000h to FFFFh
6
3
No data
4
0
0000h to 0000h
7
3
No data
4
0
0000h to 0000h
100 to
106
3
Refer to section
3.2.
4
Refer to section
3.2.
0000h to 0040h
150 to
156
3
Refer to section
3.2.
4
Refer to section
3.2.
0000h to 0040h