20 - 17
20PROFINET COMMUNICATION
20.4.3.1 Telegram Selection (P922)
PNU
Sub
Acces
s
Name
Data Type
Description
Defaul
t
922
0
R
Tgm selection
Unsigned16
The selected Telegram is returned.
1
PNU
Sub
Range
Units
EEP-ROM
Parameter
922
0
0001h to FFFFh
Impossible
The read values are as follows.
Value
Description
1
Standard telegram 1
100
Telegram 100
102
Telegram 102
103
Telegram 103
20.4.3.2 Operating mode (P930)
PNU
Sub
Access
Name
Data Type
Description
Defaul
t
930
0
R
Operating
mode
Unsigned16
The current Operating mode is
returned.
1
PNU
Sub
Range
Units
EEP-ROM
Parameter
930
0
0001h to FFFFh
Impossible
The read values are as follows.
Value
Description
1
Speed control mode (when Standard telegram 1 is selected)
32768
Manufacturer-specific mode (when Telegram is selected other than the above)
Refer to Modes of operation display (P24673) for details of the control mode.
20.4.3.3 Fault message counter (P944)
PNU
Sub
Acces
s
Name
Data Type
Description
Defaul
t
944
0
R
Fault counter
Unsigned16
The value of Fault message counter is
returned. This value will be incremented
when an alarm of driver occurs or the
alarm is released.
0
PNU
Sub
Range
Units
EEP-ROM
Parameter
944
0
0000h to FFFFh
Impossible

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks LECSN-T Series and is the answer not in the manual?

SMC Networks LECSN-T Series Specifications

General IconGeneral
BrandSMC Networks
ModelLECSN-T Series
CategoryController
LanguageEnglish

Related product manuals