19EtherNet/IP COMMUNICATION
(9) Parameter Objects PN (2581h to 25A0h)
Ins ID
Attr ID
Access
Name
Data Type
2581h
0
Get/Set
PN01
DINT
25A0h
PN32
Ins ID
Attr ID
Default
Range
Units
EEP-ROM
Parameter
2581h
0
Possible
PN01
25A0h
PN32
The values of the network setting parameters ([Pr. PN_ _ ]) can be obtained and set.
19.7.3.5 Alarm Objects (Class ID: 64h)
The instances described in this section support the following service.
When "Get" is in the "Access" field
Service Code
Name
Description
0Eh
Get_Attribute_Single
Reads the value of the specified attribute.
When "Set" is in the "Access" field
Service Code
Name
Description
10h
Set_Attribute_Single
Writes a value to the specified attribute.