19 - 127
19EtherNet/IP COMMUNICATION
(6) Parameter Objects PF (2281h to 22C0h)
Ins ID
Attr ID
Access
Name
Data Type
2281h
0
Get/Set
PF01
DINT
22C0h
PF64
Ins ID
Attr ID
Default
Range
Units
EEP-ROM
Parameter
2281h
0
Possible
PF01
22C0h
PF64
The values of the extension setting 3 parameters ([Pr. PF_ _ ]) can be obtained and set.
(7) Parameter Objects PL (2401h to 2430h)
Ins ID
Attr ID
Access
Name
Data Type
2401h
0
Get/Set
PL01
DINT
2430h
PL48
Ins ID
Attr ID
Default
Range
Units
EEP-ROM
Parameter
2401h
0
Possible
PL01
2430h
PL48
The values of the linear servo motor/DD motor setting parameters ([Pr. PL_ _ ]) can be obtained and set.
(8) Parameter Objects PT (2481h to 24D0h)
Ins ID
Attr ID
Access
Name
Data Type
2481h
0
Get/Set
PT01
DINT
24D0h
PT80
Ins ID
Attr ID
Default
Range
Units
EEP-ROM
Parameter
2481h
0
Possible
PT01
24D0h
PT80
The values of the positioning control parameters ([Pr. PT_ _ ]) can be obtained and set.