6. NORMAL GAIN ADJUSTMENT
6 - 6
6.2.2 Display transition and operation procedure of one-touch tuning
(1) Response mode selection
Select a response mode from 3 modes in the one-touch tuning window of setup software (MR
Configurator2
TM
).
Response mode
Explanation
High mode
This mode is for high-rigid system. (Note)
Basic mode
This mode is for standard system.
Low mode
This mode is for low-rigid system.
Note.
If the communication cycle of the controller is 2 ms or more, the gain may be
adjusted higher. In this case, readjust the gain in the basic mode or the low mode.