19 - 107
19EtherNet/IP COMMUNICATION
19.7.3 Object library
This section describes the details of the object library for each group.
The following is shown in the "Access" column.
"Get": Only reading is available.
"Set": Only writing is available.
"Get/Set": Reading and writing are available.
The following is shown in the "EEP-ROM" column.
"Impossible": The data is not saved to the EEP-ROM. The value of the data written from the upper side
returns to the value of "Default" when the power is shut off.
"Possible": The data can be saved to the EEP-ROM with Store Parameters (Class ID: 64h, Ins ID: 1010h).
The data is saved in the parameter corresponding to the object. For the corresponding
parameters, refer to "Parameter".