19 - 85
19EtherNet/IP COMMUNICATION
19.6.2 Instruction code
19.6.2.1 Summary
If you set the code corresponding to an item to be read/written from/to the Instruction code object through the
cyclic communication, the master can change or read parameter values and object values of a driver. The
following table lists the instruction code objects.
Name
Data Type
Access
Description
Instruction code
UDINT
Get/Set
Instruction code
Writing data
DINT
Get/Set
Writing data
Respond code
UINT
Get
Respond code
Reading data
DINT
Get
Reading data
19.6.2.2 Reading instruction codes
(1) Timing chart
ON
OFF
ON
OFF
Data reading period
Instruction code execution
demand
(Control DI 10, bit 1)
Instruction code
Instruction code execution
completion
(Status DO 10, bit 1)
Respond code
Reading data
Set the reading instruction code (refer to (2) in this section) in Instruction code and turn on Instruction
code execution demand (Control DI 10, bit 1). Turning on Instruction code execution demand (Control DI
10, bit 1) sets the data corresponding to the set reading code in Reading data. Data is all hexadecimal. At
this time, Instruction code execution completion (Status DO 10, bit 1) also turns on. Read the reading
data to be set in Reading data while Instruction code execution demand (Control DI 10, bit 1) is on. The
data set in Reading data is held until Instruction code execution demand (Control DI 10, bit 1) turns on
with the next reading instruction code set.
If an instruction code out of the specifications is set in Instruction code, an error code (_ _ 1 _) is set in
Respond code. At this time, "00000000" is stored in Reading data. Refer to section 6.2.5 for details of the
respond code.
Turn off Instruction code execution demand (Control DI 10, bit 1) after the data reading is completed.
Until Instruction code execution completion turns on after Instruction code execution demand is turned
on, do not change the instruction code. Turn off Instruction code execution demand after the data reading
is completed.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks LECSN-T Series and is the answer not in the manual?

SMC Networks LECSN-T Series Specifications

General IconGeneral
BrandSMC Networks
ModelLECSN-T Series
CategoryController
LanguageEnglish

Related product manuals