20 - 116
20PROFINET COMMUNICATION
20.8.14.1 Parameter enabling
The parameters whose symbols are preceded by * are enabled by the following operations. Refer to chapter
5 for "*" of the parameter symbol.
(1) Network disconnection
A parameter is enabled when a network disconnection switches the driver state to the state in which it
waits for the upper side to be connected.
(2) State transition
A parameter is enabled when the upper side shifts from the ProcessData communication state to another
state.
(3) Parameter enabling operation
A parameter is enabled by writing "1EA5h" to User parameter configuration object (P11572). You can
operate this when the upper side is not using the ProcessData communication. Write it with Web server
function for a upper side whose Acyclic communication is not enabled without using ProcessData
communication.
The parameter enabling processing requires a maximum of about 100 ms. The read values of the User
parameter configuration object are as follows. By checking the read value, the completion of the
parameter enabling processing can be checked.
Value
Description
0
Parameter enabling processing is being executed.
1
Parameter enabling processing is not being executed. (The processing is completed.)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks LECSN-T Series and is the answer not in the manual?

SMC Networks LECSN-T Series Specifications

General IconGeneral
BrandSMC Networks
ModelLECSN-T Series
CategoryController
LanguageEnglish

Related product manuals