Chapter 29 port Commands
Management Switch Card User’s Guide
759
enet bandwidth <slot-port> <ingress-
rate> <egress-rate>
Sets the incoming or outgoing bandwidth control
for the specified Ethernet (ELC) subscriber port(s)
(0~99968 Kbps).
ingress-rate: The incoming bandwidth rate on a
port.
egress-rate: The outgoing bandwidth rate on a
port.
8
dot3ad aggport
<slot-port>
t1|t2|…|t10|none
Creates a link aggregation trunk group for
Ethernet (ELC) subscriber ports.
8
disable <slot>
t1|t2|…|t10
Turns off link aggregation on the specified
subscriber port trunk group.
8
enable
<slot> t1|t2|…|t10
[lacp]
Turns on link aggregation on the specified
subscriber port trunk group.
lacp turns on LACP
protocol.
8
show <slot>
Displays Ethernet (ELC) subscriber port link
aggregation settings.
1
dt disable <slot-port>
Turns off double tagging on the specified ELC
subscriber port.
Note: These port enet dt commands only
support the GLC1320G-55 line cards.
8
enable <slot-port>
Turns on double tagging on the specified ELC
subscriber port. The ELC adds two VLAN tags
specified using the command to untagged frames
flowing through the port.
8
set <slot-port>
<svid> <spriority>
<cvid>
Sets the inner c-tag (customer VLAN tag), the
outer s-tag (service provider VLAN tag), and the
IEEE 802.1p priority level for the s-tag for the ELC
subscriber ports.
8
flowctrl disable <slot-port>
Turns off flow control on an ELC subscriber port. 8
enable <slot-port>
Turns on flow control on ELC subscriber port. 8
frametype <slot-port> all|tag
Sets the ELC subscriber port(s) to accept VLAN
tagged and untagged Ethernet frames or only
tagged.
8
priority <slot-port>
<priority>
Sets the ELC subscriber port(s) priority (0~7). 0 is
the lowest priority level and 7 is the highest.
8
pvlan delete <slot-port>
<etype>
Deletes the specified Protocol VLAN membership
entry for a GLC subscriber port.
Etype: This is a number of four hexadecimal digits
that specify the Ethernet type of a specific
protocol. For example, 0806 is the Ethernet type,
0x0806, for ARP (Address Resolution Protocol)
traffic. The system checks for untagged frames
with this Ethernet type.
Note: These port enet pvlan commands only
support the GLC1320G-55 line cards.
8
Table 364 port Commands (continued)
COMMAND DESCRIPTION P