EasyManua.ls Logo

ZyXEL Communications MSC1000G - Page 772

ZyXEL Communications MSC1000G
1168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 29 port Commands
Management Switch Card User’s Guide
772
sos <slot-port> xtuc|xtur
[sosminrate
<
sosminrate>] [sostime
<sostime>] [soscrc
<
soscrc>] [sosntone
<sosntone>] [sosmax
<
sosmax>] [sosenable
<disable|enable>]
[rocsnrm <rocsnrm>]
[rocmininp
<
rocmininp>]
[rocenable
<disable|enable>]
[dynamicd
<disable|enable>]
Configures SOS emergency rate reduction on the
VDSL port(s).
sosminrate : minimum bearer rate that must be
gauranteed after an SOS request, 0~100032 kbps.
sostime : duration of the SOS time window, 64 ~
16320 ms.
soscrc: minimum number of normalized CRC
anomalies, 0 ~ 65535 in units of 0.02 that must
occur during the time window to trigger SOS.
sosntone: minimum percentage of degraded tones
that must also occur throughout the time window
to trigger SOS, 0 ~ 100.
sosmax: maximum allowed number of successful
SOS procedures within 120 seconds before
triggering a full re-initialization, 0 ~ 15.
rocsnrm: extra signal-to-noise ratio margin to add
for the ROC (Robust Overhead Channel), 0 ~ 310
in 0.1 dB units.
rocmininp: required INP_no_erasure value
(impulse noise protection) for the ROC, 0 ~ 16.
rocenable: turn the use of the ROC on or off.
dynamicd: turn dynamic interleave depth
adjustment on or off.
8
tls disable <slot-port>
Disables Transparent LAN Service (TLS). The
system does not insert additional VLAN tags to
packets.
8
enable <slot-port>
Turns on Transparent LAN Service (TLS) to insert
additional VLAN tags to packets.
8
set <slot-port>
<svid> <spriority>
Sets/changes TLS settings on the VDSL port(s).
svid: The service provider VLAN ID.
spriority: The service provider IEEE 802.1p
priority setting.
8
tpstctype <slot-port> adsl
atm|ptm
Sets to use ATM or PTM encapsulation in the
Transport Protocol Specific Transmission
Convergence (TPS-TC) sub-layer for ADSL
connections. The CPE must also support the same
setting you use. So you can use PTM if the CPE
supports it, otherwise you must use ATM.
8
upbo enable
Enables the Upstream Power Back Off (UPBO)
feature.
8
disable
Disables the UPBO feature. 8
param <slot-port>
<a0> <b0> <a1> <b1>
[<a2> <b2>
ai: UPBO Ai parameter for USi (-20725~-10240 in
1/256 dBm/Hz).
bi: UPBO Bi parameter for USi (-10485~0 in 1/256
dBm/Hz).
8
show <slot-port>
Displays UPBO settings for the specified port. 8
Table 364 port Commands (continued)
COMMAND DESCRIPTION P

Table of Contents

Related product manuals