6.3.12 NVM 751_Xero/Clean 2 List
Version 1.1
General
751-339 #Y Delta Pre Near Cycle Threshold Value 140 0 65535 The Drum Cycle threshold value between Pre Near and Life End 100[Cycle] O O
751-340 #M Delta Pre Near Cycle Threshold Value 140 0 65535 The Drum Cycle threshold value between Pre Near and Life End 100[Cycle] O O
751-341 #C Delta Pre Near Cycle Threshold Value 140 0 65535 The Drum Cycle threshold value between Pre Near and Life End 100[Cycle] O O
751-342 #K Delta Pre Near Cycle Threshold Value 140 0 65535 The Drum Cycle threshold value between Pre Near and Life End 100[Cycle] O O
751-343 #Y Delta Near Cycle Threshold Value 42 0 65535 The Drum Cycle threshold value between Near and Life End 100[Cycle] O O
751-344 #M Delta Near Cycle Threshold Value 42 0 65535 The Drum Cycle threshold value between Near and Life End 100[Cycle] O O
751-345 #C Delta Near Cycle Threshold Value 42 0 65535 The Drum Cycle threshold value between Near and Life End 100[Cycle] O O
751-346 #K Delta Near Cycle Threshold Value 42 0 65535 The Drum Cycle threshold value between Near and Life End 100[Cycle] O O
751-347 #Y Life End PV Threshold Value 1000 0 65535 The Drum PV threshold value that indicates Life End 100[PV] O O
751-348 #M Life End PV Threshold Value 1000 0 65535 The Drum PV threshold value that indicates Life End 100[PV] O O
751-349 #C Life End PV Threshold Value 1000 0 65535 The Drum PV threshold value that indicates Life End 100[PV] O O
751-350 #K Life End PV Threshold Value 1000 0 65535 The Drum PV threshold value that indicates Life End 100[PV] O O
751-351 #Y Dead End PV Threshold Value 1547 0 65535 The Drum PV threshold value that indicates Dead End 100[PV] O O
751-352 #M Dead End PV Threshold Value 1547 0 65535 The Drum PV threshold value that indicates Dead End 100[PV] O O
751-353 #C Dead End PV Threshold Value 1547 0 65535 The Drum PV threshold value that indicates Dead End 100[PV] O O
751-354 #K Dead End PV Threshold Value 1547 0 65535 The Drum PV threshold value that indicates Dead End 100[PV] O O
751-355 #Y Delta Pre Near PV Threshold Value 20 0 65535 The Drum PV threshold value between Pre Near and Life End 100[PV] O O
751-356 #M Delta Pre Near PV Threshold Value 20 0 65535 The Drum PV threshold value between Pre Near and Life End 100[PV] O O
751-357 #C Delta Pre Near PV Threshold Value 20 0 65535 The Drum PV threshold value between Pre Near and Life End 100[PV] O O
751-358 #K Delta Pre Near PV Threshold Value 20 0 65535 The Drum PV threshold value between Pre Near and Life End 100[PV] O O
751-359 #Y Delta Near PV Threshold Value 6 0 65535 The Drum PV threshold value between Near and Life End 100[PV] O O
751-360 #M Delta Near PV Threshold Value 6 0 65535 The Drum PV threshold value between Near and Life End 100[PV] O O
751-361 #C Delta Near PV Threshold Value 6 0 65535 The Drum PV threshold value between Near and Life End 100[PV] O O
751-362 #K Delta Near PV Threshold Value 6 0 65535 The Drum PV threshold value between Near and Life End 100[PV] O O
751-363 #Y Drum Status 0 0 255 Drum Cartridge Status
bit0=1: Ready
bit1=2: Pre Near
bit2=4: Near
bit3=8: Life End (QualityLifeEnd)
bit4=16: Life Over
bit5=32: Life End (Dead End)
-OO
751-364 #M Drum Status 0 0 255 Drum Cartridge Status - O O
751-365 #C Drum Status 0 0 255 Drum Cartridge Status - O O
751-366 #K Drum Status 0 0 255 Drum Cartridge Status - O O
751-367 #Y Drum Maximum Usable Amount 3480 0 20000 Estimate Value of Drum PV Life 100[PV] O O
751-368 #M Drum Maximum Usable Amount 3480 0 20000 Estimate Value of Drum PV Life 100[PV] O O
751-369 #C Drum Maximum Usable Amount 3480 0 20000 Estimate Value of Drum PV Life 100[PV] O O
751-370 #K Drum Maximum Usable Amount 3480 0 20000 Estimate Value of Drum PV Life 100[PV] O O
Table 1 NVM 751_Xero/Clean 2 List
Chain-Link NVM Name
Default
Value
Minimum
value
Maximum
value Description Unit
Write
Allowed/
Protected
Can be
initialized

Table of Contents

Other manuals for Fuji Xerox DocuCentre SC2020

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fuji Xerox DocuCentre SC2020 and is the answer not in the manual?

Fuji Xerox DocuCentre SC2020 Specifications

General IconGeneral
BrandFuji Xerox
ModelDocuCentre SC2020
CategoryAll in One Printer
LanguageEnglish

Related product manuals