751-339 #Y Delta Pre Near Cycle Threshold Value 140 0 65535 The Drum Cycle threshold value between Pre Near and Life End 100[Cycle] O O
751-340 #M Delta Pre Near Cycle Threshold Value 140 0 65535 The Drum Cycle threshold value between Pre Near and Life End 100[Cycle] O O
751-341 #C Delta Pre Near Cycle Threshold Value 140 0 65535 The Drum Cycle threshold value between Pre Near and Life End 100[Cycle] O O
751-342 #K Delta Pre Near Cycle Threshold Value 140 0 65535 The Drum Cycle threshold value between Pre Near and Life End 100[Cycle] O O
751-343 #Y Delta Near Cycle Threshold Value 42 0 65535 The Drum Cycle threshold value between Near and Life End 100[Cycle] O O
751-344 #M Delta Near Cycle Threshold Value 42 0 65535 The Drum Cycle threshold value between Near and Life End 100[Cycle] O O
751-345 #C Delta Near Cycle Threshold Value 42 0 65535 The Drum Cycle threshold value between Near and Life End 100[Cycle] O O
751-346 #K Delta Near Cycle Threshold Value 42 0 65535 The Drum Cycle threshold value between Near and Life End 100[Cycle] O O
751-347 #Y Life End PV Threshold Value 1000 0 65535 The Drum PV threshold value that indicates Life End 100[PV] O O
751-348 #M Life End PV Threshold Value 1000 0 65535 The Drum PV threshold value that indicates Life End 100[PV] O O
751-349 #C Life End PV Threshold Value 1000 0 65535 The Drum PV threshold value that indicates Life End 100[PV] O O
751-350 #K Life End PV Threshold Value 1000 0 65535 The Drum PV threshold value that indicates Life End 100[PV] O O
751-351 #Y Dead End PV Threshold Value 1547 0 65535 The Drum PV threshold value that indicates Dead End 100[PV] O O
751-352 #M Dead End PV Threshold Value 1547 0 65535 The Drum PV threshold value that indicates Dead End 100[PV] O O
751-353 #C Dead End PV Threshold Value 1547 0 65535 The Drum PV threshold value that indicates Dead End 100[PV] O O
751-354 #K Dead End PV Threshold Value 1547 0 65535 The Drum PV threshold value that indicates Dead End 100[PV] O O
751-355 #Y Delta Pre Near PV Threshold Value 20 0 65535 The Drum PV threshold value between Pre Near and Life End 100[PV] O O
751-356 #M Delta Pre Near PV Threshold Value 20 0 65535 The Drum PV threshold value between Pre Near and Life End 100[PV] O O
751-357 #C Delta Pre Near PV Threshold Value 20 0 65535 The Drum PV threshold value between Pre Near and Life End 100[PV] O O
751-358 #K Delta Pre Near PV Threshold Value 20 0 65535 The Drum PV threshold value between Pre Near and Life End 100[PV] O O
751-359 #Y Delta Near PV Threshold Value 6 0 65535 The Drum PV threshold value between Near and Life End 100[PV] O O
751-360 #M Delta Near PV Threshold Value 6 0 65535 The Drum PV threshold value between Near and Life End 100[PV] O O
751-361 #C Delta Near PV Threshold Value 6 0 65535 The Drum PV threshold value between Near and Life End 100[PV] O O
751-362 #K Delta Near PV Threshold Value 6 0 65535 The Drum PV threshold value between Near and Life End 100[PV] O O
751-363 #Y Drum Status 0 0 255 Drum Cartridge Status
bit0=1: Ready
bit1=2: Pre Near
bit2=4: Near
bit3=8: Life End (QualityLifeEnd)
bit4=16: Life Over
bit5=32: Life End (Dead End)
-OO
751-364 #M Drum Status 0 0 255 Drum Cartridge Status - O O
751-365 #C Drum Status 0 0 255 Drum Cartridge Status - O O
751-366 #K Drum Status 0 0 255 Drum Cartridge Status - O O
751-367 #Y Drum Maximum Usable Amount 3480 0 20000 Estimate Value of Drum PV Life 100[PV] O O
751-368 #M Drum Maximum Usable Amount 3480 0 20000 Estimate Value of Drum PV Life 100[PV] O O
751-369 #C Drum Maximum Usable Amount 3480 0 20000 Estimate Value of Drum PV Life 100[PV] O O
751-370 #K Drum Maximum Usable Amount 3480 0 20000 Estimate Value of Drum PV Life 100[PV] O O
Table 1 NVM 751_Xero/Clean 2 List
Chain-Link NVM Name
Default
Value
Minimum
value
Maximum
value Description Unit
Write
Allowed/
Protected
Can be
initialized