DC SC2020
General
6.3.13 NVM 752_Process Control 1 List
Version 1.1
752-051 VH Upper Limit Value Calculation SW[C] 0 0 2 VH Upper Limit Calculate SW (0: VH Upper Limit Fixed Value, 1:
Variable Value with type/altitude correction, 2: Variable Value without
type/altitude correction)
-OO
752-052 VH Upper Limit Value Calculation SW[K] 0 0 2 VH Upper Limit Calculate SW (0: VH Upper Limit Fixed Value, 1:
Variable Value with type/altitude correction, 2: Variable Value without
type/altitude correction)
-OO
752-053 Ghost supported SW[YMC] 0 0 2 Ghost supported SW
0: OFF, 1: VH Lower Limit, 3: Fixed Delta V Offset
-OO
752-054 Ghost supported SW[K] 0 0 2 Ghost supported SW
0: OFF, 1: VH Lower Limit, 3: Fixed Delta V Offset
-OO
752-055 Barcode ModeSW 0 0 2 Barcode Mode Switch
Default Value 0: Follow the Mode, 1: Force ON, 2: Force OFF
-OX
752-056 Custom Mode 1 0 1 0: Normal Mode, 1: Custom Mode - O O
752-057 Toner Recovery SW 0 0 1 Normal Recovery·During Job Recovery Performing Switch (0: OFF,
1: ON)
-OO
752-058 Powe ON Determination for Recovery_SW 0 0 1 Perform Determination SW for Power ON Determination (0: Not per-
formed, 1: Perform
-OO
752-059 Installed Used CTRG supported SW 0 0 1 Installed Toner Conveyance Path Filling Operation SW in used
CTRG
-OO
752-060 Remaining Amount Estimate Method SW 0 0 1 0: Disp Time Integrated Estimate, 1: ICDC Integrated Estimate - O O
752-061 Remaining Notification SW 0 0 1 0: Normal, 1: Always PreNear - O O
752-062 Filling Toner Amount supported SW 1 0 1 0: Filling Toner Amount supported Indication OFF, 1: Filling Toner
Amount supported Indication ON
-OO
752-063 PreNear Correction during SW_EP Connection 0 0 1 SW to setup whether to conduct PreNear correction during EP Con-
nection
0: PreNear Correction OFF, 1: PreNear Correction ON
-OO
752-064 Delta Humidity Selection SW_Setup Performing Require-
ment
1 0 1 Delta Humidity Selection SW_Setup Performing Requirement - O O
752-065 Delta Humidity Selection SW_Target Value 1 0 1 Delta Humidity Selection SW_Target Value - O O
752-066 Delta Humidity Selection SW_Disp 1 0 1 Delta Humidity Selection SW_Disp - O O
752-067 Delta Humidity Selection SW_Potential 1 0 1 Delta Humidity Selection SW_Potential - O O
752-068 Delta Humidity Selection SW_Device 1 0 1 Delta Humidity Selection SW_Device - O O
752-069 Transfer VH Send Information SW 1 0 1 Transfer VH Send Information SW - O O
752-070 Transfer LUT_SW[Copy] 1 0 1 Transfer LUT Selection SW - O O
752-071 Transfer LUT_SW[Print] 1 0 1 Transfer LUT Selection SW - O O
752-072 ADC Sensor System Fail 0 0 65535 ADC Sensor System Fail - O O
752-073 ADC Sensor Fail Counter 0 0 65535 ADC Sensor Fail Counter - O O
752-074 ADC Potential Patch Fail Counter[Y] 0 0 65535 ADC Potential Patch Fail Counter - O O
752-075 ADC Potential Patch Fail Counter[M] 0 0 65535 ADC Potential Patch Fail Counter - O O
752-076 ADC Potential Patch Fail Counter[C] 0 0 65535 ADC Potential Patch Fail Counter - O O
Table 1 NVM 752_Process Control 1 List