05/2014
6-98
DC SC2020
6.3.13 NVM 752_Process Control 1 List
Version 1.1
General
752-030 Delta RADC_Tone_Target All Correcting SW[Patch4] 1 0 1 Delta RADC_Tone_Target All Correcting Switch - O O
752-031 Delta RADC_TC_Target All Correcting SW 1 0 1 Delta RADC_TC_Target All Correcting Switch - O O
752-032 Delta RADC_TC_Target RDP Correction Amount Clear
SW
0 0 1 Delta RADC_TC_Target RDP Correction Amount Clear SW - O O
752-033 Delta RADC_TC_Target Toner Refill Control Correction
Amount Clear SW
0 0 1 Delta RADC_TC_Target Toner Refill Control Correction Amount
Clear SW
-OO
752-034 Disp Control SW_Long Length 0 0 1 Dispense Control Switch for Long Length Paper (0: OFF, 1: ON) - O O
752-035 No. of FlagDispMotor Rotation Correction_New Toner
Cartridge
1 0 1 Selection Flag for No. of DispMotor Rotation Correction of New Car-
tridge Period
-OO
752-036 Correct No. of FlagDispMotor Rotation_recovery Mode 0 0 1 Selection Flag for No. of DispMotor Rotation Correction during Ton-
erRecovery Operation
-OO
752-037 No. of FlagDispMotor Rotation Correction_NearEmpty
Detection
0 0 1 Selection Flag for No. of DispMotor Rotation Correction after
NearEmpty Detection
-OO
752-038 No. of FlagDispMotor Rotation_Normal Operation 0 0 1 Selection Flag for No. of DispMotor Rotation Correction during Nor-
mal Operation
-OO
752-039 ADC Toner Refill Control SW[YMC] 0 0 3 SW to instruct to perform ADC Toner Refill Process - O O
752-040 ADC Toner Refill Control SW[K] 0 0 3 SW to instruct to perform ADC Toner Refill Process - O O
752-041 Contrast Ratio Maintenance Control SW 0 0 1 Contrast Ratio Maintenance Control Switch (0: OFF, 1: ON)
* This is for Image CF and there is a separate one for Mini Patch
-OO
752-042 Contrast Ratio Maintenance Control SW_Mini Patch 0 0 1 Contrast Ratio Maintenance Control Switch for Mini Patch
0: OFF, 1: ON
-OO
752-043 Reflecting Split SW after Mid/TCSetup 0 0 1 Reflecting Split Switch after Mid/TCSetup (0: Batch Reflect, 1: Split
Reflect)
-OO
752-044 Potential Reference Selection SW_Standard 1 0 1 Potential Reference Selection SW_Standard (0: VB Reference, 1: RP
Reference)
-OO
752-045 Potential Reference Selection SW_Mini 1 0 1 Potential Reference Selection SW_Mini (0: VB Reference, 1: RP Ref-
erence)
-OO
752-046 Potential Reference Selection SW_TC 1 0 1 Potential Reference Selection SW_TC (0: VB Reference, 1: RP Ref-
erence)
-OO
752-047 Potential Reference Selection SW_PCON 1 0 1 Potential Reference Selection SW_PCON (0: VB Reference, 1: RP
Reference)
-OO
752-048 CF_PCON Calculation SW 0 0 1 CF_PCON Calculation Method SW
0: Contrast Ration Standard, 1: Setting CF
-OO
752-049 VH Upper Limit Value Calculation SW[Y] 0 0 2 VH Upper Limit Calculate SW (0: VH Upper Limit Fixed Value, 1:
Variable Value with type/altitude correction, 2: Variable Value without
type/altitude correction)
-OO
752-050 VH Upper Limit Value Calculation SW[M] 0 0 2 VH Upper Limit Calculate SW (0: VH Upper Limit Fixed Value, 1:
Variable Value with type/altitude correction, 2: Variable Value without
type/altitude correction)
-OO
Table 1 NVM 752_Process Control 1 List
Chain-Link NVM Name
Default
Value
Minimum
value
Maximum
value Description Unit
Write
Allowed/
Protected
Can be
initialized