General
6.3.15 NVM 755_Process Control 4 List
Version 1.1
755-357 VH_PCON[M] 400 0 1023 PCON potential VH value - O O
755-358 VH_PCON[C] 400 0 1023 PCON potential VH value - O O
755-359 VH_PCON[K] 400 0 1023 PCON potential VH value - O O
755-360 VB_PCON[YMC] 290 0 1023 PCON potential VB value - O O
755-361 VB_PCON[K] 290 0 1023 PCON potential VB value - O O
755-362 Vdeve_Standard [Y] 270 1 1023 Standard Potential Vdeve Value - O O
755-363 Vdeve_Standard [M] 270 1 1023 Standard Potential Vdeve Value - O O
755-364 Vdeve_Standard [C] 270 1 1023 Standard Potential Vdeve Value - O O
755-365 Vdeve_Standard [K] 270 1 1023 Standard Potential Vdeve Value - O O
755-366 CF_Standard [Y] 110 1 1023 Standard Potential CF Value - O O
755-367 CF_Standard [M] 110 1 1023 Standard Potential CF Value - O O
755-368 CF_Standard [C] 110 1 1023 Standard Potential CF Value - O O
755-369 CF_Standard [K] 110 1 1023 Standard Potential CF Value - O O
755-370 RP[Y] 10 0 1023 RP Value - O O
755-371 RP[M] 10 0 1023 RP Value - O O
755-372 RP[C] 10 0 1023 RP Value - O O
755-373 RP[K] 10 0 1023 RP Value - O O
755-374 Contrast Ratio_MiniSetup[Y] 314 1 65535 Contrast Ratio of MiniSetup used for CF_PCON Calculation SW=1:00 - O O
755-375 Contrast Ratio_MiniSetup[M] 314 1 65535 Contrast Ratio of MiniSetup used for CF_PCON Calculation SW=1:00 - O O
755-376 Contrast Ratio_MiniSetup[C] 314 1 65535 Contrast Ratio of MiniSetup used for CF_PCON Calculation SW=1:00 - O O
755-377 Contrast Ratio_MiniSetup[K] 314 1 65535 Contrast Ratio of MiniSetup used for CF_PCON Calculation SW=1:00 - O O
755-378 No. of Vdeve_PCON Partition 1 1 255 PCON Potential Vdeve Value_No. of Partition - O O
755-379 Delta VB_Vdeve Correction Amount
[YMC][Current]
0 -511 511 Delta VB_Vdeve Correction Amount - O O
755-380 Delta VB_Vdeve Correction Amount
[YMC][Last]
0 -511 511 Delta VB_Vdeve Correction Amount - O O
755-381 Delta VB_Vdeve Correction Amount [K][Cur-
rent]
0 -511 511 Delta VB_Vdeve Correction Amount - O O
755-382 Delta VB_Vdeve Correction Amount [K][Last] 0 -511 511 Delta VB_Vdeve Correction Amount - O O
755-383 BCR_DC Correction Offset_Estimate [Y] 572 -1024 1023 BCR for Estimate Potential_DC Correction Offset Value - O O
755-384 BCR_DC Correction Offset_Estimate [M] 572 -1024 1023 BCR for Estimate Potential_DC Correction Offset Value - O O
755-385 BCR_DC Correction Offset_Estimate [C] 572 -1024 1023 BCR for Estimate Potential_DC Correction Offset Value - O O
755-386 BCR_DC Correction Offset_Estimate [K] 572 -1024 1023 BCR for Estimate Potential_DC Correction Offset Value - O O
755-387 BCR_DC Correction Coefficient_Estimate [Y] 1054 0 65535 BCR for Estimate Potential_DC Correction Coefficient - O O
755-388 BCR_DC Correction Coefficient_Estimate [M] 1054 0 65535 BCR for Estimate Potential_DC Correction Coefficient - O O
755-389 BCR_DC Correction Coefficient_Estimate [C] 1054 0 65535 BCR for Estimate Potential_DC Correction Coefficient - O O
755-390 BCR_DC Correction Coefficient_Estimate [K] 1054 0 65535 BCR for Estimate Potential_DC Correction Coefficient - O O
755-391 Standard LPH[Y] 677 0 2046 Standard LPH - O O
Table 1 NVM 755_Process Control 4 List
Chain-Link NVM Name
Default
Value
Minimum
value
Maximum
value Description Unit
Write
Allowed/
Protected
Can be
initialized

Table of Contents

Other manuals for Fuji Xerox DocuCentre SC2020

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fuji Xerox DocuCentre SC2020 and is the answer not in the manual?

Fuji Xerox DocuCentre SC2020 Specifications

General IconGeneral
BrandFuji Xerox
ModelDocuCentre SC2020
CategoryAll in One Printer
LanguageEnglish

Related product manuals