05/2014
6-173
DC SC2020
General
6.3.19 NVM 762_Deve 2 List
Version 1.1
6.3.19 NVM 762_Deve 2 List
Table 1 NVM 762_Deve 2 List
Chain-Link NVM Name
Default
Value
Minimum
value
Maximum
value Description Unit
Write
Allowed/
Protected
Can be
initialized
762-025 Deve Temperature Raise Band Switch 0 0 1 Temperature Raise Band Execution Selection Switch
0: Do not Execute, 1: Perform
-OO
762-038 #Y Temperature Raise Bank Average A/C 0 0 1000 Average A/C calculated when Temperature Raise Band is decided 0.1[%] O O
762-039 #M Temperature Raise Band Average A/C 0 0 1000 Average A/C calculated when Temperature Raise Band is decided 0.1[%] O O
762-040 #C Temperature Raise Band Average A/C 0 0 1000 Average A/C calculated when Temperature Raise Band is decided 0.1[%] O O
762-041 #K Temperature Raise Band Average A/C 0 0 1000 Average A/C calculated when Temperature Raise Band is decided 0.1[%] O O
762-042 Y No. of times Temperature Raise Band was cre-
ated
0 0 20000 No. of times Temperature Raise Band was created. * Clear with HFSI
reset
Times O O
762-043 M No. of times Temperature Raise Band was cre-
ated
0 0 20000 No. of times Temperature Raise Band was created. * Clear with HFSI
reset
Times O O
762-044 C No. of times Temperature Raise Band was cre-
ated
0 0 20000 No. of times Temperature Raise Band was created. * Clear with HFSI
reset
Times O O
762-045 K No. of times Temperature Raise Band was cre-
ated
0 0 20000 No. of times Temperature Raise Band was created. * Clear with HFSI
reset
Times O O
762-046 Temperature Raise Band Width Integrated Value Y 0 0 50000000 Temperature Raise Band Width Integrated Value. * Clear with HFSI reset 0.1[mm] O O
762-047 Temperature raise Band Width Integrated Value M 0 0 50000000 Temperature Raise Band Width Integrated Value. * Clear with HFSI reset 0.1[mm] O O
762-048 Temperature Raise Band Width Integrated Value C 0 0 50000000 Temperature Raise Band Width Integrated Value. * Clear with HFSI reset 0.1[mm] O O
762-049 Temperature Raise Band Width Integrated Value K 0 0 50000000 Temperature Raise Band Width Integrated Value. * Clear with HFSI reset 0.1[mm] O O
762-050 Decay Agitation Execution SW 0 0 1 Decay Agitation Execution SW
0: Do not execute Entry Determination, 1: Execute Entry determination
-OO
762-051 Decay Entry Threshold Value 7 0 30 Decay Entry Threshold Value [hour]
(For comparison with the time from the Deve Motor Off to the Entry Deter-
mination)
-OO
762-052 Decay Temperature Determination Threshold Value 25 0 30 Decay Temperature Determination Threshold Value [degrees] (To com-
pare with the temp during Entry)
-OO
762-053 Decay Humidity Determination Threshold Value 75 0 100 Decay Humidity Determination Threshold Value [%] (To compare with the
temp during Entry)
-OO
762-054 Store SubMot Stop Time (BW) 0 0 4294967295 Acquires the stop time of Sub Motor during BW Mode. minute O O
762-055 Store SubMot Stop Time (FC) 0 0 4294967295 Acquires the stop time of Sub Motor during FC Mode. minute O O
762-056 Decay Setup Length 7560 0 30160 Decay Panel Length mm O O
762-057 DEVE Reverse Rotation SW 0 0 3 DEVE Reverse Rotation Perform SW
0: Do not perform, 1: Execute only in BW, 2: Execute only in FC, 3: Exe-
cute in all Modes
-OO
762-058 DEVE Reverse Rotation PV Threshold Value 40 0 1000 DEVE Reverse Rotation PV Threshold Value PV O O
762-059 DEVE Reverse Rotation Time 100 50 200 DEVE Reverse Rotation PV 10[ms] O O
762-060 Auger Mark Countermeasure SW 0 0 1 Performance Switch for Auger Mark Countermeasure
0: Do not perform, 1: Perform
-OO