6.3.19 NVM 762_Deve 2 List
Version 1.1
General
762-061 Auger Mark Countermeasure Temperature Thresh-
old Value
27 0 100 Performance Determination Temperature Threshold Value for Auger Mark
Countermeasure
Perform when the temperature is above than this.
Degree O O
762-062 Auger Mark Countermeasure Humidity Threshold
Value
75 0 100 Performance Determination Humidity Threshold Value for Auger Mark
Countermeasure
Perform when the humidity is above than this.
%OO
762-063 Auger Mark Countermeasure Time Threshold Value 45 0 2500 Performance Determination Time Threshold Value for Auger Mark Coun-
termeasure
Perform then the developing machine drive time with 63mm/s is more than
this threshold value.
Seconds O O
762-064 Auger Mark Countermeasure YMC Time Threshold
Value Adjustment Ratio
50 1 100 YMC Auger Mark Countermeasure Time Threshold Value Adjustment
Ratio from Auger Mark Countermeasure of K is performed.
Make 1~100% of [Auger Mark Countermeasure Time Threshold Value].
%OO
762-065 Auger Mark Countermeasure Perform Time 40 1 100 No-Loading Time when Auger Mark Countermeasure is performed Seconds O O
762-080 Deve Low A/C Band Switch 1 0 2 Deve Low A/C Band Execution Selection Switch
0: Do not Execute, 1: Perform, 2: Perform with Control Mode]
Performance Judgement A/C Threshold Value, A/C Target Value changes
in Control Mode
-OO
762-081 Deve Low A/C Band Creation Interval 40 0 200 ADC MID Demand determination Interval PV O O
762-082 ADC MID Request Judgement Band Width Thresh-
old Value
1950 1000 10000 ADC MID Request Judgement Band Width Threshold Value. *Use only
when judging the MID SET Request when Deve Low A/C Band Determi-
nation Interval is reached
0.1[mm] O O
762-083 High Load Determination No. of sheets 600 0 8000 High Load Mode Determination Threshold Value sheets O O
762-084 Mid Load Determination No. of sheets 100 0 8000 Mid Load Mode Determination Threshold Value sheets O O
762-085 Low R/L Determination Threshold Value 32 0 255 If the PV per 1 Job is lower than this Threshold Value, conduct the Deve
Low A/C Band Control in Low R/L Mode.
0.1
[sheets]
OO
762-086 A4L Deve Cycle count Reduced Value (In High R/L
Mode)
157 10 250 No. of Deve rotation equivalent to A4L (For High R/L Mode): FC_R/L100
Trial Calculation Value
(Used for Load Determination as well)
0.1[Cycle] O O
762-087 A4L Deve Cycle count Reduced Value (In Low R/L
Mode)
183 10 250 No. of Deve rotation equivalent to A4L (For Low R/L Mode): FC_R/L2 Trial
Calculation Value
0.1[Cycle] O O
762-088 Deve Low A/C Toner Band density 100 60 100 Deve Low A/C Toner Band Density % O O
762-089 Deve Low A/C Toner Band Width Upper Limit 2400 1000 10000 Deve Low A/C Toner Band Width Upper Limit 0.1[mm] O O
762-090 No. of Deve Low A/C Toner Band Created Y 0 0 20000 No. of Deve Low A/C Toner Band Created * Clear with HFSI reset Times O O
762-091 No. of Deve Low A/C Toner Band Created M 0 0 20000 No. of Deve Low A/C Toner Band Created * Clear with HFSI reset Times O O
762-092 No. of Deve Low A/C Toner Band Created C 0 0 20000 No. of Deve Low A/C Toner Band Created * Clear with HFSI reset Times O O
762-093 No. of Deve Low A/C Toner Band Created K 0 0 20000 No. of Deve Low A/C Toner Band Created * Clear with HFSI reset Times O O
762-094 Deve Low A/C Toner Band Width Integrated Value
Y
0 0 50000000 Deve Low A/C Toner Band Width Integrated Value. * Clear with HFSI
reset
0.1[mm] O O
762-095 Deve Low A/C Toner Band Width Integrated Value
M
0 0 50000000 Deve Low A/C Toner Band Width Integrated Value. * Clear with HFSI
reset
0.1[mm] O O
Table 1 NVM 762_Deve 2 List
Chain-Link NVM Name
Default
Value
Minimum
value
Maximum
value Description Unit