05/2014
6-175
DC SC2020
General
6.3.19 NVM 762_Deve 2 List
Version 1.1
762-096 Deve Low A/C Toner Band Width Integrated Value
C
0 0 50000000 Deve Low A/C Toner Band Width Integrated Value. * Clear with HFSI
reset
0.1[mm] O O
762-097 Deve Low A/C toner Band Width Integrated Value K 0 0 50000000 Deve Low A/C Toner Band Width Integrated Value. * Clear with HFSI
reset
0.1[mm] O O
762-098 Deve Low A/C Band Perform Determination A/C
Threshold Value
(Low R/L, Low Load, Non-Control Mode)
20 0 1000 Deve Low A/C Band Perform Determination A/C Threshold Value
During Low R/L, Low Load, Non-Control Mode
0.1[%] O O
762-099 Deve Low A/C Band Perform Determination A/C
Threshold Value
(Low R/L, Low Load, Control Mode)
5 0 1000 Deve Low A/C Band Perform Determination A/C Threshold Value
When Low R/L, Low Load, Control Mode
0.1[%] O O
762-100 Deve Low A/C Band Perform Determination A/C
Threshold Value
(Low R/L, Mid Load, Non-Control Mode)
20 0 1000 Deve Low A/C Band Perform Determination A/C Threshold Value
During Low R/L, Mid Load, Non-Control Mode
0.1[%] O O
762-101 Deve Low A/C Band Perform Determination A/C
Threshold Value
(Low R/L, Mid Load, Control Mode)
5 0 1000 Deve Low A/C Band Perform Determination A/C Threshold Value
During Low R/L, Mid Load, Control Mode
0.1[%] O O
762-102 Deve Low A/C Band Perform Determination A/C
Threshold Value
(Low R/L, High Load, Non-Control Mode)
20 0 1000 Deve Low A/C Band Perform Determination A/C Threshold Value
During Low R/L, High Load, Non-Control Mode
0.1[%] O O
762-103 Deve Low A/C Band Perform Determination A/C
Threshold Value
(Low R/L, High Load, Control Mode)
5 0 1000 Deve Low A/C Band Perform Determination A/C Threshold Value
During Low R/L, High Load, Control Mode
0.1[%] O O
762-104 Deve Low A/C Band Perform Determination A/C
Threshold Value
(High R/L, Low Load, Non-Control Mode)
23 0 1000 Deve Low A/C Band Perform Determination A/C Threshold Value
During High R/L, Low Load, Non-Control Mode
0.1[%] O O
762-105 Deve Low A/C Band Perform Determination A/C
Threshold Value
(High R/L, Low Load, Control Mode)
5 0 1000 Deve Low A/C Band Perform Determination A/C Threshold Value
During High R/L, Low Load, Control Mode
0.1[%] O O
762-106 Deve Low A/C Band Perform Determination A/C
Threshold Value
(High R/L, Mid Load, Non-Control Mode)
23 0 1000 Deve Low A/C Band Perform Determination A/C Threshold Value
During High R/L, Mid Load, Non-Control Mode
0.1[%] O O
762-107 Deve Low A/C Band Perform Determination A/C
Threshold Value
(High R/L, Mid Load, Control Mode)
5 0 1000 Deve Low A/C Band Perform Determination A/C Threshold Value
During High R/L, Mid Load, Control Mode
0.1[%] O O
762-108 Deve Low A/C Band Perform Determination A/C
Threshold Value
(High R/L, High Load, Non-Control Mode)
23 0 1000 Deve Low A/C Band Perform Determination A/C Threshold Value
During High R/L, High Load, Non-Control Mode
0.1[%] O O
762-109 Deve Low A/C Band Perform Determination A/C
Threshold Value
(High R/L, High Load, Control Mode)
5 0 1000 Deve Low A/C Band Perform Determination A/C Threshold Value
During High R/L, High Load, Control Mode
0.1[%] O O
762-110 A/C Target Value after performing Deve Low A/C
Band
(Low R/L, Low Load, Non-Control Mode)
5 0 1000 Set the Band width to supplement the A/C shortage in this target value
when performing Deve Low A/C Band. During Low R/L, Low Load, Non-
Control Mode
0.1[%] O O
Table 1 NVM 762_Deve 2 List
Chain-Link NVM Name
Default
Value
Minimum
value
Maximum
value Description Unit
Write
Allowed/
Protected
Can be
initialized