6.3.19 NVM 762_Deve 2 List
Version 1.1
General
762-111 A/C Target Value after performing Deve Low A/C
Band
(Low R/L, Low Load, Control Mode)
5 0 1000 Set the Band width to supplement the A/C shortage in this target value
when performing Deve Low A/C Band. When Low R/L, Low Load, Control
Mode
0.1[%] O O
762-112 A/C Target Value after performing Deve Low A/C
Band
(Low R/L, Mid Load, Non-Control Mode)
10 0 1000 Set the Band width to supplement the A/C shortage in this target value
when performing Deve Low A/C Band. During Low R/L, Mid Load, Non-
Control Mode
0.1[%] O O
762-113 A/C Target Value after performing Deve Low A/C
Band
(Low R/L, Mid Load, Control Mode)
5 0 1000 Set the Band width to supplement the A/C shortage in this target value
when performing Deve Low A/C Band. During Low R/L, Mid Load, Control
Mode
0.1[%] O O
762-114 A/C Target Value after performing Deve Low A/C
Band
(Low R/L, High Load, Non-Control Mode)
22 0 1000 Set the Band width to supplement the A/C shortage in this target value
when performing Deve Low A/C Band. During Low R/L, High Load, Non-
Control Mode
0.1[%] O O
762-115 A/C Target Value after performing Deve Low A/C
Band
(Low R/L, High Load, Control Mode)
5 0 1000 Set the Band width to supplement the A/C shortage in this target value
when performing Deve Low A/C Band. During Low R/L, High Load, Con-
trol Mode
0.1[%] O O
762-116 A/C Target Value after performing Deve Low A/C
Band
(High R/L, Low Load, Non-Control Mode)
8 0 1000 Set the Band width to supplement the A/C shortage in this target value
when performing Deve Low A/C Band. During Low R/L, Low Load, Non-
Control Mode
0.1[%] O O
762-117 A/C Target Value after performing Deve Low A/C
Band
(High R/L, Low Load, Control Mode)
5 0 1000 Set the Band width to supplement the A/C shortage in this target value
when performing Deve Low A/C Band. When Low R/L, Low Load, Control
Mode
0.1[%] O O
762-118 A/C Target Value after performing Deve Low A/C
Band
(High R/L, Mid Load, Non-Control Mode)
16 0 1000 Set the Band width to supplement the A/C shortage in this target value
when performing Deve Low A/C Band. During Low R/L, Mid Load, Non-
Control Mode
0.1[%] O O
762-119 A/C Target Value after performing Deve Low A/C
Band
(High R/L, Mid Load, Control Mode)
5 0 1000 Set the Band width to supplement the A/C shortage in this target value
when performing Deve Low A/C Band. During Low R/L, Mid Load, Control
Mode
0.1[%] O O
762-120 A/C Target Value after performing Deve Low A/C
Band
(High R/L, High Load, Non-Control Mode)
28 0 1000 Set the Band width to supplement the A/C shortage in this target value
when performing Deve Low A/C Band. During Low R/L, High Load, Non-
Control Mode
0.1[%] O O
762-121 A/C Target Value after performing Deve Low A/C
Band
(High R/L, High Load, Control Mode)
5 0 1000 Set the Band width to supplement the A/C shortage in this target value
when performing Deve Low A/C Band. During Low R/L, High Load, Con-
trol Mode
0.1[%] O O
762-163 Deve Low A/C Band Calculation A/C Y 0 0 1000 Deve Low A/C Band Calculation A/C Value Y 0.1[%] O O
762-164 Deve Low A/C Band Calculation A/C M 0 0 1000 Deve Low A/C Band Calculation A/C Value M 0.1[%] O O
762-165 Deve Low A/C Band Calculation A/C C 0 0 1000 Deve Low A/C Band Calculation A/C Value C 0.1[%] O O
762-166 Deve Low A/C Band Calculation A/C K 0 0 1000 Deve Low A/C Band Calculation A/C Value K 0.1[%] O O
762-167 Deve Load A/C Band Calculation Load Mode Y 0 0 2 Deve Low A/C Band Calculation Load Mode Y
0: Low Load, 1: Mid Load, 2: HIgh Load
-OO
762-168 Deve Low A/C Band Calculation Load Mode M 0 0 2 Deve Low A/C Band Calculation Load Mode M
0: Low Load, 1: Mid Load, 2: HIgh Load
-OO
Table 1 NVM 762_Deve 2 List
Chain-Link NVM Name
Default
Value
Minimum
value
Maximum
value Description Unit
Write
Allowed/
Protected
Can be
initialized