Introduction
Term description
The meanings of terms used in this operation manual are as follows:
Terms Description
AeroDR SYSTEM
• Collective term indicating DR Detector, AeroDR Interface Unit, AeroDR Interface Unit2, AeroDR
Generator Interface Unit, AeroDR Generator Interface Unit2, AeroDR Battery Charger, AeroDR
Battery Charger2, AeroDR Access Point, etc.
• Collective term indicating AeroDR SYSTEM, AeroDR SYSTEM 2 and SKR3000.
DR Detector
Collective term indicating AeroDR 1417HQ, AeroDR 1417S, AeroDR 1717HQ, AeroDR
1012HQ, AeroDR 2 1417HQ, AeroDR 2 1417S and AeroDR 3 1417HD.
AeroDR Interface Unit
Supplies power to the AeroDR Generator Interface Unit, AeroDR Generator Interface Unit2,
and access point, and supplies power to and charges the battery of the DR Detector when
wired cables are used. It also has a hub function.
AeroDR Interface Unit2
• Supplies power to the access point, and supplies power to and charges the battery of the
DR Detector when wired cables are used. It also has a hub function.
• Relays signals between the X-ray device, the DR Detector, and the CS-7.
AeroDR Generator Interface Unit Relays signals between the X-ray device, the DR Detector, and this device.
AeroDR Generator Interface Unit2 Relays signals between the X-ray device, the DR Detector, and this device.
AeroDR Battery Charger Charges the DR Detector. It also has the registration function for the DR Detector.
AeroDR Battery Charger2 Charges the DR Detector. It also has the registration function for the DR Detector.
Access point Collective term indicating AeroDR Access Point and a general-purpose access point.
I/F Cable
Use with the DR detector wired connection. It also includes the DR detector charging and
registration functions.
AeroDR UF Cable
In the case of capturing images with the wall stand and table, register the DR detector
direction.
AeroDR Portable RF Unit
Receives an image data from the DR Detector and transfers it to this device. Also, this unit
interfaces with the portable X-ray device.
AeroDR Portable RF Unit2
• Interfaces with the mobile X-ray device.
• Charges or registers the DR Detector when using the AeroDR Battery Charging KIT and
AeroDR I/F Cable2.
AeroDR Portable UF Unit Receives an image data from the DR Detector and transfers it to this device.
AeroDR Stitching System Used when performing stitching exposures using the DR Detector.
Calibration Processing for calibrating the characteristics of the DR Detector for each pixel
CR An acronym for computed radiography
DR An acronym for digital radiography
JM An acronym for job manager
REGIUS
Collective term indicating the REGIUS series (Excluding "REGIUS SIGMA" and "REGIUS
SIGMA2").
When indicated individually, they are shown as "REGIUS 110", "REGIUS 110HQ",
"REGIUS 210", "REGIUS 190", and "REGIUS 170".
REGIUS SIGMA/SIGMA2 Used as the collective terms for "REGIUS SIGMA" and "REGIUS SIGMA2".
CR cassette
Used as the collective terms for the cassettes in the REGIUS series and REGIUS SIGMA/
SIGMA2.