387
10.2 Error codes and countermeasures
Chapter 10
Error code Displayed message Problems/countermeasures
C27600 -
C27604
Initialization Error
Check the destination connected to.
C27605 Health check error
C27606 -
C27608
Scheduled check error
C2761* Error in study completed notication to RIS
C27620 -
C27626
Patient search error
C27628
C27629
C2763*
C2764*
Folder check error
C2770*
C2773*
Communication error occurred in RIS-OUT communi-
cation.
Check the communication destination.
Check the network status.
C2774*
Communication error occurred in RIS-IN communica-
tion.
Check the communication destination.
10.2.2 Software errors
Error codes starting with "C3" through "C7" are indicating software errors.
Error code Displayed message Problems/countermeasures
C35500
Failed to initialize. Restart this device.
C35501 There was an error with reading the setting le. Check the setting le and update it.
C35502
A time-out occurred.
MWM search request response waiting time-out oc-
curred.
Check the connection destination.
C35503 A socket error occurred.
An error occurred in communication with DICOM.
(1) Check the destination connected to, the network
status, and connection settings.
(2) Restart the device.
C35504 Channel mismatch occurred Contact Konica Minolta technical representatives.
C35520 Failed to initialize. Restart this device.
C35521 There was an error with reading the setting le. Check the setting le and update it.
C35522
A time-out occurred.
PPS result notication time-out occurred.
Check the connection destination.
C35540 Failed to initialize. Restart this device.
C35541 There was an error with reading the setting le. Check the setting le and update it.
C35542
A time-out occurred.
Detach result notication response timeout occurred.
Check the connection destination.
C35543 Channel mismatch occurred
Contact Konica Minolta technical representatives.
C35560 Failed to initialize.
C35561 There was an error with reading the setting le.
C35562
A time-out occurred.
C35563 Socket error has occurred.
Check the network equipment and communication
cable connection status.
C35564 Exceeded the maximum number of strings obtained. Contact Konica Minolta technical representatives.
C36020 At PrintComposer process, execution error occurred.
(1) Try performing the operation again.
(2) Contact Konica Minolta technical representatives.
C36021
At PrimtComposer process, Fatal error occurred. Con-
tact a service representative.
Contact Konica Minolta technical representatives.
Continued on the next page