294
7.12 Multi-study
Number Name Functions
(3) Status Icon
: Unexposed
: Exposed (Saved)
: Outputting
: Output nished
: Paused
: In progress
: Finished (Exposed)
: Delete
(4)
Examination item
list
Examination item list is dis-
played.
(5) Add Study button
Adds an examination item to
the examination item list.
(6) Get Study button
Carries out MWM using the
patient information on the ex-
posure screen as the search
key. If an examination that
is not included in the dis-
played examination item list
is found, that examination is
additionally displayed.
(7)
Output Image
button
Outputs images that have
not been output in the exami-
nation items selected using
the button. This outputs on
an examination item basis.
(8)
Delete Study but-
ton
Deletes the examination
selected with the button from
the examination item list.
Exposure screen ([Exam.Tag] tab screen)
(7)(6)(5)
(1)
(2)
(3)
(4)
Number Name Functions
(1) Exam. Tag tab
Displays the Exam. Tag tab
screen.
(2)
Exposure switch-
ing button
Pressing [ ] displays
the rst page of the exposure
item list, and [ ] displays
the last page. In this way,
you can switch the target
examination to be exposed.
This section describes the screen structure of the ex-
posure screen and procedure of examination when
performing examination with the multi-study.
In multi-study, individual order items displayed in the
Study List are referred to as examinations.
In addition, a single exposure taken for each examina-
tion unit displayed in the Exam. List is referred to as an
exposure.
IMPORTANT
•••••••••••••••••••••••••••••••••••••
Multi-study and real-time back up cannot be used
simultaneously.
If the total number of exposures surpasses 512, fur-
ther examinations cannot be acquired. If the Get Study
button is pressed and the total number of exposures
surpasses 512, an error message is displayed.
•••••••••••••••••••••••••••••••••••••••••••••••••••••
7.12.1 Screen structure
Structure of the screen when performing examination
with the multi-study is as follows.
Exposure screen ([Study List] tab screen)
(6)
(3)
(7) (8)
(4)
(5)
(1)
(2)
Number Name Functions
(1) Study List tab
Displays the Study List tab
screen.
(2)
Study switching
button
Pressing [ ] displays the
rst page of the examination
item list, and [ ] displays
the last page. In this way,
you can switch the target
examination to be exposed.

Table of Contents