Motorola RF Switch CLI Reference Guide
25-32
retry-threshold : 14.0 averaged retries/packet
hold-time : 3600 seconds
Smart-RF Calibration Schedule:
schedule calibration : disabled
schedule first-start : Sat Mar 29 03:30:00 2009
schedule interval : 1 day(s)
Smart-RF Run Time Monitor and Recovery configuration:
recover interference : enabled
recover neighbor : enabled
recover coverage-hole : enabled
Diagnostic configuration:
Verbose Mode : disabled
Extensive Scan Mode : disabled
RFSwitch(config-wireless-smart-rf)#
RFS7000(config-wireless-smart-rf)#show wireless smart-rf
calibration-status
Smart-RF Calibration is busy at delay-second
Smart Master IP: 0.0.0.0
My IP: 0.0.0.0
Cluster Master : yes
Last Calibration Started at: Sun Sep 7 06:01:48 2009
Last Calibration Ended at: Sun Sep 7 06:01:48 2009
Next calibration Starts at: not scheduled
RFSwitch(config-wireless-smart-rf)#
RFSwitch(config-wireless-smart-rf)#show wireless smart-rf
history
Smart Master IP: 0.0.0.0
My IP: 0.0.0.0
Cluster Master : yes
Last Calibration Started at: Sun Sep 7 06:03:33 2009
Last Calibration Ended at: Sun Sep 7 06:03:33 2009
Next calibration Starts at: not scheduled