RTLS Instance
21-15
Usage Guidelines
Use [no] service [options] to rollback any service related configurations.
Example
RFSwitch(config-rtls)#service filter 1 length 1
RFSwitch(config-rtls)#
start-trigger – Configures start trigger for tag inventory
gpi – Configures GPI event based start trigger
port <1-65535> – Configures GPI port number
event <0-1> – Configures a boolean GPI event value
that causes GPI event to trigger
timeout <0-65535> – Configures trigger1 timeout in
miliiseconds
immediate – Starts tag inventory immediately
periodic – Configures periodic tag inventory
offset <0-65535> – Configures time offset in
milliseconds
period <0-65535> – Configures time period in
milliseconds
stop-trigger – Configures stop trigger for tag inventory
duration <0-65535> – Configures duration in
milliseconds
gpi – Configures GPI event based start trigger
port <1-65535> – Configures GPI port number
event <0-1> – Configures a boolean GPI event value
that causes GPI event to trigger
timeout <0-65535> – Configures trigger timeout in
miliiseconds
immediate – Stops tag inventory immediately
zone <1-48> – Configures the selected logical reader
show cli