RTLS Instance
21-15
Usage Guidelines
Use [no] service [options] to rollback any service related configurations.
Example
RFSwitch(config-rtls)#service filter 1 length 1
RFSwitch(config-rtls)#
• start-trigger – Configures start trigger for tag inventory
• gpi – Configures GPI event based start trigger
• port <1-65535> – Configures GPI port number
• event <0-1> – Configures a boolean GPI event value
that causes GPI event to trigger
• timeout <0-65535> – Configures trigger1 timeout in
miliiseconds
• immediate – Starts tag inventory immediately
• periodic – Configures periodic tag inventory
• offset <0-65535> – Configures time offset in
milliseconds
• period <0-65535> – Configures time period in
milliseconds
• stop-trigger – Configures stop trigger for tag inventory
• duration <0-65535> – Configures duration in
milliseconds
• gpi – Configures GPI event based start trigger
• port <1-65535> – Configures GPI port number
• event <0-1> – Configures a boolean GPI event value
that causes GPI event to trigger
• timeout <0-65535> – Configures trigger timeout in
miliiseconds
• immediate – Stops tag inventory immediately
• zone <1-48> – Configures the selected logical reader
show cli
Show running system information
• cli – Show CLI tree of current mode

Table of Contents

Other manuals for Motorola RFS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motorola RFS Series and is the answer not in the manual?

Motorola RFS Series Specifications

General IconGeneral
BrandMotorola
ModelRFS Series
CategorySwitch
LanguageEnglish

Related product manuals