Remote control commandsMXO 4 Series
768User Manual 1335.5337.02 ─ 07
17.16.5.2 Trigger
Trigger commands for serial buses affect the current trigger source. Therefore, set the
trigger source to the required serial bus with TRIGger:EVENt<ev>:SOURce before
sending the bus-specific trigger commands.
TRIGger:CAN:TYPE.......................................................................................................768
TRIGger:CAN:DCONdition..............................................................................................769
TRIGger:CAN:DMIN.......................................................................................................769
TRIGger:CAN:FDATa:DPOSition......................................................................................770
TRIGger:CAN:DLC.........................................................................................................770
TRIGger:CAN:DLCCondition........................................................................................... 770
TRIGger:CAN:FTYPe..................................................................................................... 770
TRIGger:CAN:ICONdition............................................................................................... 771
TRIGger:CAN:IMAX....................................................................................................... 771
TRIGger:CAN:IMIN........................................................................................................ 771
TRIGger:CAN:ITYPe...................................................................................................... 772
TRIGger:CAN:FORMerror...............................................................................................772
TRIGger:CAN:FDATa:SCERror........................................................................................772
TRIGger:CAN:ACKerror..................................................................................................773
TRIGger:CAN:BITSterror................................................................................................ 773
TRIGger:CAN:CRCerror................................................................................................. 773
TRIGger:CAN:FDATa:BRS.............................................................................................. 773
TRIGger:CAN:FDATa:ESI............................................................................................... 774
TRIGger:CAN:XDATa:AF:CONDition................................................................................774
TRIGger:CAN:XDATa:AF:MAX........................................................................................ 774
TRIGger:CAN:XDATa:AF:MIN......................................................................................... 775
TRIGger:CAN:XDATa:SDT:CONDition..............................................................................775
TRIGger:CAN:XDATa:SDT:MAX...................................................................................... 775
TRIGger:CAN:XDATa:SDT:MIN....................................................................................... 775
TRIGger:CAN:XDATa:SEC..............................................................................................776
TRIGger:CAN:XDATa:VCID:CONDition............................................................................ 776
TRIGger:CAN:XDATa:VCID:MAX.....................................................................................776
TRIGger:CAN:XDATa:VCID:MIN......................................................................................776
TRIGger:CAN:TYPE <Type>
Selects the trigger type for CAN analysis.
Parameters:
<Type> STOF | EDOF | FTYP | ID | IDDT | ERRC
STOF
STart of Frame: triggers on the first edge of the dominant SOF
bit (synchronization bit).
FTYP
Frame type: triggers on a specified frame type and on the identi-
fier format.
Protocols