Remote control commands
R&S
®
RTP
1372User Manual 1337.9952.02 ─ 12
<MeasType>
parameter value
(remote control)
Measurement
(manual opera-
tion)
Description, result Suffix
<n>
SHR Setup/Hold ratio Setup/Hold ratio measurement. Setup/Hold ratio is the
ratio of the setup time to the sum of hold and setup time:
T
Setup
/
(T
Setup
+
T
Hold
)
Use this parameter as setting to activate the Setup/Hold
ratio measurement in:
MEASurement<m>:MAIN on page 1364
MEASurement<m>:ADDitional on page 1365
It is also used in the following queries:
MEASurement<m>:ARES?
MEASurement<n>:RESult:..
Used also in queries with and commands.
36
Used for jitter measurements (limit checks) see Chapter 22.22.1, "Jitter measurements (option
R&S RTP-K12)", on page 2256.
37 to
45
DTOTrigger Delay to trigger Time between the trigger event and a following signal
slope. High accuracy even if the trigger event is outside
the acquisition data.
46
PROBemeter Trig. ProbeMeter DC voltage measured by the connected active R&S
probe
47
SLERising Slew rate on ris-
ing edge
Steepness of the rising edge: voltage difference between
the lower and higher reference level, divided by the rise
time.
48
SLEFalling Slew rate on fall-
ing edge
Steepness of the falling edge: voltage difference
between the higher and lower reference level, divided by
the fall time.
49
ATAR Arithmetic for
amplitude/time
measurements
Basic arithmetic calculations with measurement values
and scalars.
50
MEASurement<m>:ENVSelect...................................................................................... 1373
MEASurement<m>:DETThreshold.................................................................................1373
MEASurement<m>:AMPTime:ALEVel............................................................................ 1373
MEASurement<m>:AMPTime:PFSLope......................................................................... 1374
MEASurement<m>:AMPTime:PSLope........................................................................... 1374
MEASurement<m>:AMPTime:DELay<n>:DIRection........................................................ 1375
MEASurement<m>:AMPTime:DELay<n>:ECOunt........................................................... 1375
MEASurement<m>:AMPTime:DELay<n>:LSELect.......................................................... 1375
MEASurement<m>:AMPTime:DELay<n>:SLOPe............................................................ 1376
MEASurement<m>:AMPTime:PTCount.......................................................................... 1376
MEASurement<m>:AMPTime:ESLope........................................................................... 1377
MEASurement<m>:AMPTime:CSLope........................................................................... 1377
MEASurement<m>:AMPTime:CLCK<n>:LSELect........................................................... 1377
MEASurement<m>:AMPTime:DATA<n>:LSELect............................................................1378
MEASurement<m>:AMPTime:DTOTrigger<n>:SLOPe.....................................................1378
MEASurement<m>:AMPTime:DTOTrigger<n>:LSELect................................................... 1378
MEASurement<m>:AMPTime:LCHeck<n>:VALid............................................................ 1379
MEASurement<m>:AMPTime:LCHeck<n>:LOWer:LIMit...................................................1379
MEASurement<m>:AMPTime:LCHeck<n>:UPPer:LIMit................................................... 1379