"Condition"
Sets the comparison condition to a specific value or a range.
"RTA Min/
RTA"
Specifies the value or sets the start value of a range.
"RTA Max"
Sets the maximum value of a range for "Condition" = "In range"/"Out
of range".
Remote command: 
TRIGger<m>:MILStd:CDST:RCONdition on page 1689
TRIGger<m>:MILStd:CDST:RMAX on page 1690
TRIGger<m>:MILStd:CDST:RMIN on page 1690
TRIGger<m>:MILStd:CMD:RCONdition on page 1689
TRIGger<m>:MILStd:CMD:RMAX on page 1690
TRIGger<m>:MILStd:CMD:RMIN on page 1690
TRIGger<m>:MILStd:DATA:RCONdition on page 1689
TRIGger<m>:MILStd:DATA:RMAX on page 1690
TRIGger<m>:MILStd:DATA:RMIN on page 1690
Data Pattern
Sets the data to be triggered on. The trigger data setup consists of a comparison con-
dition and one or two data patterns.
In binary format, use the following characters: 1; 0; or X (do not care). To enter the pat-
tern in other formats use the bit pattern editor, see Chapter 13.1.7, "Bit pattern editor",
on page 519.
"Condition"
Sets the comparison condition to a specific value or a range.
"Data Min/
Data"
Specifies the value or sets the start value of a range.
"Data Max"
Sets the maximum value of a range for "Condition" = "In range"/"Out
of range".
Remote command: 
TRIGger<m>:MILStd:DATA:DCONdition on page 1693
TRIGger<m>:MILStd:DATA:DMAX on page 1693
TRIGger<m>:MILStd:DATA:DMIN on page 1694
Data Index
The MIL-MIL-STD-1553 standard defines the length of a message to a series of up to
32 words. Data index sets the range within this series of the data words that is consid-
ered for the analysis. The data index setup consists of the condition and one or two
data index values.
"Condition"
Sets the comparison condition to a specific value or a range.
"Index Min/Index"
Specifies the value or sets the start value of a range.
"Index Max"
Sets the maximum value of a range for "Condition" = "In range"/"Out
of range".